4 INSTALLATION
4.1 GSL
Install flexible hose, secured with hose clamps
at both ends, from feed tube to material inlet
tube of loader. A Proportioning Valve, if
included (see separate instructions) is installed
on the material inlet tube with a compression
style coupling.
115 VAC
Power Cord
Material Line
Connection
GSL Mounting Plate
(see page 3)
Connect Fitting on
Solenoid Valve to
Compressed Air
(Pilot for Blowback)
Locate HINGE away from
operator for easy cleaning
1
2
3
Control Pendant
(see page 6)
Feed Tube
Inserted into material
Plastic
Pellets
1
Install flexible compressed air line to the
solenoid valve fitting (below lid hinge). Source
should provide clean, dry compressed air supply
80 -100 psi. Use only full-flow quick disconnect
fitting for best blowback performance.
CAUTION: Use a second wrench to hold the
fitting on the GSL securely while tightening the
hose fitting. DO NOT apply direct pressure, or
damage the GSL fitting or an air leak could
result. A compressed air filter (sold separately)
is recommended for protection of pneumatic
components.
Plug power cord into 115 VAC power
source. Note amperage listing on loader
for correct voltage and capacity.
1
2
3
Domed filter
stays in place
when tilted.