Conair S900II System Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 46
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
III – 2. The robot axes
III – 2. 1. General axes’ parameters
PARAMETER
Abbreviation Description Criterion Corresponding value and function
610
746
882
TYP_AXE_X
TYP_AXE_Y
TYP AXE Z
Definition of the type of axis
Type of motorization
0 = Axis not installed.
1 = Brushless.
2 = Asynchronous
882
1018
TYP_AXE_Z
TYP_AXE_B
Type of initialization
0 = Initialization on cam and Init pulse.
16 = Initialization on cam only.
1154
TYP_AXE_C
Initialization forced when powered
up
0 = If the axis is stopped when the robot is powered
down, it relocates its position when powered up.
32 = The axis must be initialized each time the robot is
powered up (it will not return to the position at the time
it was powered down).
Counting directions
0 = Counting increases.
64 = Counting decreases.
Type of speed dr
i
ver
Asynchronous:
0 = Speed reference +/– 10V and validation input.
128 = Speed reference 0 – 10V and + direction and
– direction inputs.
Type o
f
speed dr
i
ver
Brushless:
0 = Validation input only
128 = Validation input and speed or power supply
reference selection input.
Type of regulator
0 = Validation of proportional regulator (P)
256 = Validation of PFC predictive regulator (option)