III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
PARAMETER Abbreviation Description Parameter
value
Corresponding function
622
758
894
1030
1166
VREG_X
VREG_Y
VREG_Z
VREG_B
VREG_C
Maximum speed in adjust
mode in millimetres per
second (mm/s).
1 –> 1000
Value of the maximum movement speed in adjust mode. Used to limit the
maximum speed in adjust mode.
Default value :
150
Possible value : 1 –> 1000 Interaction with other parameters :
623
759
895
1031
1167
AREG_X
AREG_Y
AREG_Z
AREG_B
AREG_C
Maximum acceleration in
adjust mode in milllimetres
per square second (mm/s
2
).
1 –> 50000
Value of maximum acceleration in adjust mode. Used to limit maximum
acceleration in adjust mode.
Default value :
500
Possible value : 1 –> 50000 Interaction with other parameters :