III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
PARAMETER Abbreviation Description Parameter
value
Corresponding function
1298
1312
KPULSES_N1
KPULSES_N2
Conversion multiplier factor.
1 –> 10000
A complement of parameter 1296, it is the multiplier coefficient of the conversion
coefficient.
Conversion factor = parameter 1298 * parameter 1296 / 100
Default value :
0
Possible value : 1 –> 10000 Interaction with other parameters : 1296, 1310
1300
1314
TOLER_N1
TOLER_N2
Speed tolerance
1 –> 6000
In the case of speed monitoring, the value of the window in which the “following”
axis is considered as locked onto the measured axis.
Default value :
0
Possible value : 1 –> 6000 Interaction with other parameters :