I – Parameter definition
S900–II Configuration
Version 2.1
10
01T01506_1
25.11.99
PARAMETER Abbreviation Description Parameter
value
Corresponding function
0006
TIMOUT_ST
Time–Out value between
steps in 1/10 seconds
0000
–>
9999
Indicates the authorised waiting time for a control (input or bit) in a step
before the fault D_10 appears.
Its validity is conditionned by parameter No. 7.
Default value :
50
Possible value :
0 –> 9999
Interaction with other parameters : 7
0007
DEF_TIMOUT
Type of Time–Out between
steps
0 Fault for the main program (PRG) and the parallel subroutine (SPP).
1 Fault for the parallel subroutine (SPP), just signalled for the main
program (PRG).
2 Fault for the main program (PRG), just signalled for the parallel
subroutine (SPP).
3 No fault, just signalled for the main program (PRG) and the
parallel subroutine (SPP).
A software “watchdog” whose length is set by parameters (No 6 and 8) constantly overlooks the sequential running of the program.
If there is a delay between 2 steps greater than that of the “watchdog” (input or bit absent), the robot goes into fault D_10 .
However, there are cases when you do not want to be in fault mode. It is therefore possible to set the fault mode or signalling parameters
globally : in a main program (PRG) and/or in a parallel subroutine (SPP)
Default value :
0
Possible value :
0 –> 3
Interaction with other parameters : 6, 8