I – Parameter definition
S900–II Configuration
Version 2.1
6
01T01506_1
25.11.99
PARAMETER Abbreviation Description Parameter
value
Corresponding function
0002
CTRL_PRISE
Type of part grip controls 0 Standard control PP1 to PP8.
1 Control by bit 32.
The part presence can be controlled by detection (vacuum switch, end of course, proximity sensor, ...) or can be associated with the status of
a bit, (bit 32) the result of a more complex equation (multiple part grips) carried out by the PLC.
Checking by bit 32 is only valid with the PIP interface (parameter 171 = 1 or 2) and only for part grip in the IMM.
Default value :
0
Possible value :
0 –> 1
Interaction with other parameters : 171
0003
COD_NUM_PP
Type of program number
encoding
0 None.
1 Encoding limited to number on 4 inputs + parity input.
Max : 16 programs (N° 0 to 15).
2 Encoding extended to number on 7 inputs + parity input.
Max : 100 programs (N° 0 to 99).
3 Number encoded by the IMM with Euromap 17 (WWORD 102).
4 Number encoded by supervisor word with JBUS option
(MotCod 1, Word 58).
The table on the following page shows the encoding for the 100 programs in pure binary. 1 represents the bit weighted 1 (parameter 540), 2
represents the bit weighted 2 (parameter 541), 4 represents the bit weighted 4 (parameter 542), ...8 –> 543, 16 –> 544, 32 –> 545, 64 –> 546
and p represents the parity bit (parameter 547)*.
Default value :
0
Possible value :
0 –> 4
Interaction with other parameters : 4, 540 –> 547
* The binary code must contain an even number of inputs at 1 to be valid. Therefore, set the parity bit to 1 or 0.
Note : You are strongly advised not to use program number 0 as, if there is no encoding, this program is selected.