I – Parameter definition
S900–II Configuration
Version 2.1
27
01T01506_1
25.11.99
PARAMETER Abbreviation Description Parameter
value
Corresponding function
0172
TAKE_PART_1
Type of reset of the part made
memory
0 Disappearance of the “IMM in automatic or semi–automatic” data item
(parameter 498) or disappearance of the “gate closed” signal (parameter
496) or pressing the pendant RESET key resets the part made memory to
zero.
1 Disappearance of the “IMM in automatic or semi–automatic” data item
(parameter 498) or disappearance of the “gate closed” signal (parameter
496) triggers a stop at the end of the cycle and the question “Part to be
taken in the MOULD ?“ is asked.
V 1.3 robot
V 0.5 PC Editor
2 The part made memory is only reset to zero by an operator reset. See
parameter 173.
Default value :
0
Possible value :
0 –> 2
Interaction with other parameters : 173, 496, 498
0173
RESET_1
Part reset to restart the IMM 0 Using the RESET key of the pendant only.
1 Using the RESET button of the IMM 1 restart box only (BRP1).
2 Using the pendant RESET key or the RESET button of the IMM 1 restart box
(BRP1).
3 Part made memory is not reset.
Default value :
0
Possible value :
0 –> 3
Interaction with other parameters : 1, 172